ATOMIC ABSORPTION
Single Element Hollow Cathode Lamps
Description
Similar to
OEM Part No.
Agilent
Part No.
Aluminum Al 50 mm coded N3050103 8003-0712
Antimony Sb 50 mm coded N3050170 8003-0713
Arsenic As 50 mm coded  N3050105 8003-0714
Barium Ba 50 mm coded N3050109 8003-0715
Beryllium Be 50 mm coded N3050110 8003-0716
Bismuth Bi 50 mm coded N3050111 8003-0888
Boron B 50 mm coded N3050108 8003-0889
Cadmium Cd 50 mm coded N3050115 8003-0890
Calcium Ca 50 mm coded N3050114 8003-0891
Chromium Cr 50 mm coded N3050119 8003-0892
Cobalt Co 50 mm coded N3050118 8003-0893
Copper Cu 50 mm coded N3050121 8003-0894
Europium Eu 50 mm coded N3050124 8003-0897
Gadolinium Gd 50 mm coded N3050129 8003-0898
Gallium Ga 50 mm coded N3050128 8003-0899
Germanium Ge 50 mm coded N3050130 8003-0900
Gold Au 50 mm coded N3050107 8003-0901
Indium In 50 mm coded N3050137 8003-0904
Iridium Ir 50 mm coded N3050138 8003-0905
Iron Fe 50 mm coded N3050126 8003-0906
Lanthanum La 50 mm coded N3050141 8003-0907
Lead Pb 50 mm coded N3050157 8003-0908
Lithium Li 50 mm coded N3050142 8003-0909
(Continued)

Nebulizers and Components
Instrument  Description
Similar to
OEM Part No.
Agilent
Part No.
PinAAcle Capillary assembly for stainless steel nebulizer N3160113 8003-0827
PinAAcle Nebulizer assembly, stainless steel, for aqueous solutions N3160143 8003-0828
PinAAcle O-ring, for high-sensitivity nebulizer with Pt/Ir capillary B0507708 8003-0862
PinAAcle Capillary assembly, for metal body nebulizers 03030354 8003-0864
PinAAcle Nebulizer, high-sensitivity, with Pt/Ir capillary N3160144 8003-0950
PinAAcle and AAnalyst
100/200/300/400/700/800
Impact bead, for high-sensitivity nebulizer with Pt/Ir or tantalum capillary
and earlier AA models
B0505086 8003-0860
PinAAcle and AAnalyst 200/400 O-ring, for high-sensitivity nebulizer with Pt/Ir capillary 09902015 8003-0861
PinAAcle and AAnalyst 200/400 Spring, for high-sensitivity nebulizer with Pt/Ir capillary 09920483 8003-0865

Single Element Hollow Cathode Lamps
Description
Similar to
OEM Part No.
Agilent
Part No.
Magnesium Mg 50 mm coded N3050144 8003-0910
Manganese Mn 50 mm coded N3050145 8003-0911
Mercury Hg 50 mm coded N3050134 8003-0912
Molybdenum Mo 50 mm coded N3050146 8003-0913
Neodymium Nd 50 mm coded N3050150 8003-0914
Nickel Ni 50 mm coded N3050152 8003-0915
Niobium Nb 50 mm coded N3050149 8003-0916
Palladium Pd 50 mm coded N3050158 8003-0917
Phosphorus P 50 mm coded N3050155 8003-0918
Platinum Pt 50 mm coded N3050162 8003-0919
Potassium K 50 mm coded N3050139 8003-0920
Praseodymium Pr 50 mm coded N3050161 8003-0921
Rhenium Re 50 mm coded N3050165 8003-0922
Rhodium Rh 50 mm coded N3050166 8003-0923
Samarium Sm 50 mm coded N3050174 8003-0924
Scandium Sc 50 mm coded N3050171 8003-0925
Selenium Se 50 mm coded N3050172 8003-0926
Silicon Si 50 mm coded N3050173 8003-0927
Silver Ag 50 mm coded N3050102 8003-0928
Sodium Na 50 mm coded N3050148 8003-0929
Strontium Sr 50 mm coded N3050176 8003-0930
Tantalum Ta 50 mm coded N3050177 8003-0931
Tellurium Te 50 mm coded N3050180 8003-0932
Thallium Tl 50 mm coded N3050183 8003-0934
Tin Sn 50 mm coded N3050175 8003-0936
Titanium Ti 50 mm coded N3050182 8003-0937
Tungsten W 50 mm coded N3050187 8003-0938
Vanadium V 50 mm coded N3050186 8003-0939
Yttrium Y 50 mm coded N3050189 8003-0941
Zinc Zn 50 mm coded N3050191 8003-0942
Zirconium Zr 50 mm coded N3050192 8003-0943

Nebulizers and Components
Instrument  Description
Similar to
OEM Part No.
Agilent
Part No.
All PE AA systems Nebulizer cleaning wire, alloy, 5/pk 03030135 9910024700
All PE AA systems Nebulizer capillary tubing, polyethylene, 10 ft (3 m), 0.023 inch (0.6 mm) id x
0.038 inch (0.97 mm) od, used with Cross-Flow and high solids nebulizer
09908265 8003-0406
AAnalyst 200/400 Nebulizer, high-sensitivity, with Pt/Ir capillary N3150188 8003-0837
AAnalyst 100/200/300/400/700/800 Capillary assembly, for corrosion-resistant nebulizer 03030402 8003-0818
AAnalyst 100/200/300/400/700/800 Nebulizer assembly, corrosion-resistant 03030404 8003-0819
AAnalyst 100/200/300/400/700/800 Nebulizer assembly, stainless steel, for aqueous solutions 03030352 8003-0822
AAnalyst 100/200/300/400/700/800 O-ring kit, for metal body nebulizer assemblies N9300065 8003-0826
AAnalyst 100/300/700/800 Spring, for GemTip nebulizer 09902473 8003-0830
AAnalyst 100/300/700/800 GemTip nebulizer assembly, high-sensitivity N0370393 8003-0831
AAnalyst 100/300/700/800 GemTip nebulizer assembly N0370394 8003-0832
AAnalyst 100/300/700/800 Spring, for high-sensitivity nebulizer with Pt/Ir capillary B0165332 8003-0833
AAnalyst 100/300/700/800 O-ring, for high-sensitivity nebulizer with Pt/Ir capillary B0506143 8003-0834
AAnalyst 100/300/700/800 O-ring, for high-sensitivity nebulizer with tantalum capillary B0190672 8003-0835
AAnalyst 100/300/700/800 Nebulizer, high-sensitivity, with Pt/Ir capillary B0505480 8003-0836
AAnalyst 100/300/700/800 O-ring, 9.25 mm id, 1.78 mm cross section (2-012), for high-sensitivity nebulizer
with Pt/Ir capillary
B0174378 8003-0863
AAnalyst 200/400
and PinAAcle 900
Nebulizer tubing assembly, for high-sensitivity nebulizer with Pt/Ir capillary B3150458 8003-0409
AAnalyst 100/200/300/400/
700/800 and PinAAcle 900
Capillary assembly, for metal body nebulizers
Capillary assembly, for high-sensitivity nebulizer with Pt/Ir capillary
03030354 8003-0864
700/800 and PinAAcle 900 Spring, for metal body nebulizer assemblies 03031806 8003-0823
Capillary assembly, for high-sensi-tivity nebulizer with Pt/Ir capillary
03030354 8003-0864
O-ring, 0.208 inch id, 0.070 inch cross section, for stainless steel
nebulizer assembly
09902239 8003-0824
AAnalyst 100/200/300/400/
700/800 and PinAAcle
O-ring, 0.176 inch id x 0.070 inch cross section, for stainless steel
nebulizer assembly
09902005 8003-0825

Burner System Components
Instrument  Description
Similar to
OEM Part No.
Agilent
Part No.
Parts for PinAAcle Systems
PinAAcle 900 End cap latch assembly N3160107 8003-0838
PinAAcle 900 Burner drain assembly for organics N3150232 8003-0854
PinAAcle O-ring, end cap, 0.312 x 0.070 inch (4 required) 09200253 8003-0842
PinAAcle End cap assembly, for metal body nebulizers N3160102 8003-0845
PinAAcle End cap assembly, for plastic body nebulizers N3160111 8003-0847
PinAAcle Burner drain assembly, with tubing and drain interlock,
drain bottle not included
N0400058 8003-0857
PinAAcle Burner mixing chamber assembly N3160506 8003-0944
Parts for PinAAacle & AAnalyst Systems
PinAAcle and AAnalyst
100/200/300/400/700/800
Flow spoiler 00572561 8003-0841
PinAAcle and AAnalyst
100/200/300/400/700/800
O-ring, end cap, Viton, standard 09902147 8003-0843
PinAAcle and AAnalyst
100/200/300/400/700/800
O-ring, 1/8 in x 3 mm id, for seal plug in end cap assembly
for metal body nebulizers
09902236 8003-0853
Parts for AAnalyst Systems
AAnalyst 100/200/300/400/700/800 Clamping ring, for burner system N0401171 8003-0840
AAnalyst 100/200/300/400/700/800 O-ring, end cap, Kalrez, organics/aqueous 09921044 8003-0844
AAnalyst 100/200/300/400/700/800 End cap assembly, for metal body nebulizers 00570984 8003-0820
AAnalyst 100/200/300/400/700/800 End cap assembly, for plastic body nebulizers N0370392 8003-0848
AAnalyst 100/200/300/400/700/800 Drain tubing, Tygon, with FEP lining 02507987 8003-0850
AAnalyst 100/200/300/400/700/800 Seal plug, Pyrex, for impact bead used with end cap assembly
for metal body nebulizers
00572624 8003-0851
Burner System Components
Instrument  Description
Similar to
OEM Part No.
Agilent
Part No.
Parts for AAnalyst Systems
AAnalyst 100/200/300/400/700/800 O-ring, 1/4 inch x 6 mm id, for end cap assembly for metal body nebulizers 09902240 8003-0852
AAnalyst 100/200/300/400/700/800 Burner drain assembly for organics N3150230 8003-0855
AAnalyst 100/200/300/400/700/800 Burner drain assembly, with tubing and drain interlock, drain bottle not included N2011074 8003-0856
AAnalyst 100/200/300/400/700/800 Burner mixing chamber assembly 00570948 8003-0945
Burner Supplies
Instrument  Description
Similar to
OEM Part No.
Agilent
Part No.
AAnalyst 100/200/300/400/700/800 Burner gasket kit for end cap assembly for metal body nebulizers  00470988 8003-0395
AAnalyst 100/200/300/400/700/800 O-ring kit, Viton for burner head 09902219 8003-0397
AAnalyst 100/200/300/400/700/800 Gasket (O-ring), Corkprene, for burner end cap organics 00472014 8003-0407
PinAAcle and AAnalyst O-ring, burner head, 24.99 x 3.53 mm 09200079 8003-0849
PinAAcle and AAnalyst 100/200/300/400/700/800 Burner head cleaning tool 03031573 8003-0858
Burners
Instrument  Description
Similar to
OEM Part No.
Agilent
Part No.
PinAAcle and AAnalyst 100/200/300/400/700/800 Burner head, single-slot, 5 cm, for nitrous oxide-acetylene
or air-acetylene operation
N0400100 8003-0417
PinAAcle and AAnalyst 100/200/300/400/700/800 Burner head, single-slot, 5 cm, for air-acetylene operation N0400101 8003-0418
PinAAcle and AAnalyst 100/200/300/400/700/800 Burner head, single-slot, 10 cm, for air-acetylene operation N0400102 8003-0419
Graphite Components
Instrument  Description
Similar to
OEM Part No.
Agilent
Part No.
Graphite Tubes and Platforms
THGA Graphite Furnace Systems Graphite tube, standard, THGA, with end cap, 5/pk
Recommended for improved characteristic mass with volatile and medium
refractory elements (not recommended for refractory elements such as V or Ba).
B3000653 8003-0958
THGA Graphite Furnace Systems Graphite tube, standard, THGA, with integrated platform, 5/pk B3000641 8003-0410
THGA Graphite Furnace Systems Graphite tube, standard, THGA, with integrated platform, 20/pk B0504033 8003-0959
HGA-900/850/800/
700/600/300 Furnaces
Graphite tube, pyrocoated, HGA, with integrated spherically shaped platform that
accommodates up to 50 µL sample, for volatile and nonvolatile refractory elements, 5/pk
B3001262 8003-0416
HGA-900/850/800/
700/600/300 Furnaces
Graphite tube, pyrocoated, with grooves for L’vov platforms (platform not included), 10/pk B0121092 8003-0421
HGA-900/850/800/
700/600/300 Furnaces
L’vov platforms, for use with HGA tubes that have internal grooves, 20/pk B3001256 8003-0422
HGA-900/850/800/
700/600/300 Furnaces
L’vov platforms, for use with HGA tubes that have internal grooves, 10/pk B0121091 8003-0960
HGA-900/850/800/700/
600/300 Furnaces
Graphite tube, pyrocoated, HGA, 10/pk
Not compatible with L’vov platforms.
B0135653 8003-0962
HGA-900/850/800/700/
600/300 Furnaces
Graphite tube, pyrocoated, HGA, with advanced platform, 5/pk N9307834 8003-0954
Contact Cylinders
THGA Graphite Furnace Systems Contact cylinder, graphite, standard, THGA, 1 set B0504035 8003-0401
THGA Graphite Furnace Systems Modified THGA contact cylinder set
With modified injection port area to help minimize condensation and improve
analytical performance with difficult matrices.
B3002103 8003-0949
HGA-900/850/800/700/
600/300 Furnaces
Contact cylinder, HGA, 1 set
Includes left-hand contact, right-hand contact and shield ring.
B0128495 8003-0405
Zeeman HGA-900/850/800/
700/600/300 Furnaces
Contact cylinder, Zeeman, HGA, 1 set  B0116823 8003-0961
Graphite tube, standard, THGA,
8003-0410
Graphite tube, pyrocoated, HGA,
with integrated platform, 8003-0416
Graphite tube, pyrocoated, HGA,
0800-0962
(Continue
Graphite Components
Instrument  Description
Similar to
OEM Part No.
Agilent
Part No.
Tools and Other Supplies
HGA-900/850/800/700/600/300 Furnaces Insertion tool for L’vov platforms B0112657 8003-0423
THGA Graphite Furnace Systems Spare graphite tip, for fume extraction system B0506722 8003-0955
THGA Graphite Furnace Systems Filter cartridge, THGA AA600 Fume Extractor, 50/pk B0509065 8003-0956

THGA Graphite Furnace Systems O-ring (behind contact cylinder, front and back) B0500748 8003-0957